0102030405
High Current Short-circuit Testing Machine from China Suppliers - Reliable Factory for Electrical Safety Testing
Technical Specifications
| Model | TA-DL5000A~20000A (customized) |
| Control method | Remote computer control + video surveillance |
| Max short circuit current | DC5000A~DC20000A (customized) |
| Contactor |
1st type: Resistance < 5mΩ: Pneumatic vacuum copper short-circuit contactor 2nd type: 1mΩ~100mΩ Industrial high current silver surface contactor |
| Arc extinguishing method | |
| Contact corresponding time |
1st type: ≤20ms 2nd type: ≤2ms |
| Temp range | Room temperature / high temperature (customizable) |
| Device internal resistance |
1st type: resistance < 5mΩ (system short-circuit internal resistance) 2nd type: Adjustable resistance value of 1mΩ to 100mΩ or higher (optional) |
| Insulation resistance | DC1500V, 100MΩ Above (between terminal block and side panel) |
| Withstand Voltage | AC1500V, 1min, leakage current ≤ 5mA |
| Resistance material | Constantan |
| Resistance temperature sensing characteristics | ≤50ppm/℃ |
| Temperature coefficient of resistance | α = 5×10⁻⁶ [(0~100℃) 1/℃] |
| Resistivity | ρ(20℃) = 4.4×10⁻⁷ Ω·m |
| Cooling method | Forced air cooling of fan |
| Explosion proof box (optional) |
(1) Volume: 1m³ / 1.5m³ / 2m³ / 4m³ / 6m³ / 8m³ / 12m³ customizable (2) Steel plate thickness: 5mm / 8mm / 10mm / 12mm; Single or double layered, customizable |
| Collection |
(1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature (2) Number of channels; Range; Accuracy; The collection frequency can be customized (3) Collection can be built-in or external; External brands are optional |
| Test cut-off shutdown conditions | The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions |
| Curve | Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance |
| Data Interface | Network interface |
| Safety device | Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc. |
| Security protection design | Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm |
| Power supply | AC220V (AC380V) 50HZ 3kW |
| Air source |
The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa Multi resistor short-circuit host does not require air source |
| Size |
Air arc extinguishing short circuit host: W700 × D1050 × H1650mm Multi resistance high current short-circuit host: W2000 × D1550 × H1750mm (subject to design) |
| Weight |
Vacuum arc extinguishing short-circuit host: 400kg Multi resistance high current short-circuit host: 1500kg (subject to design) |
Key Highlights
- 🛡️ Explosion-Proof Safety DesignEquipped with explosion-proof devices, double-layer explosion-proof steel structure and explosion-proof glass observation windows.
- 📊 High-Precision Data AcquisitionSupports real-time monitoring of voltage, current, and temperature, as well as curve display.
- ⚡ Efficient Arc Extinguishing SystemEffectively suppresses the generation of arcs, prolongs the service life of the contactors.
- 🔧 Multifunctional Integrated SystemIntegrates a temperature control box, smoke extinguishing system, and video monitoring system into one.
Compliance & Standards
Safety Systems
🏗️
Physical Protection
Explosion-proof cabinet, pressure relief structure, automatic smoke exhaust.
🌡️
Environmental Monitoring
Intelligent fire extinguishing system.
🔌
Electrical Protection
Emergency stop button, overload protection, short-circuit isolation.
Application
- Testing of power batteries for new energy vehicles
- Performance testing of battery cells and modules for energy storage systems (BESS)
- Special testing for research institute laboratories
- Quality inspection of consumer electronic batteries
Service & Support
- 📅 Regular CalibrationAssist in the annual calibration of the equipment to ensure test accuracy.
- 🔩 Installation & CommissioningOffer on-site installation and commissioning services along with professional technical training.
- 📞 Rapid ResponseProvide 24/7 round-the-clock technical support.
Workflow
FAQ
-
This is a common safety hazard existing in the high current test. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured; in case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating.
-
The current during a short circuit changes extremely rapidly (at the millisecond level). Therefore, the equipment adopts a high sampling rate data acquisition module (100kHz and above) combined with high-precision current sensors (such as Rogowski coils, high-frequency shunts, etc.), which can completely capture and record the instantaneous current waveform, ensuring the authenticity and completeness of the test data.
-
Yes. The equipment supports a wide range of voltage levels from DC5V to DC1500V. All you need to do is set the corresponding protection threshold in the software interface, thus truly achieving multi-purpose use with a single machine.
-
The equipment is designed to support testing in compliance with major international and Chinese standards including UN38.3, IEC 62133, UL 2580, GB 31241, GB/T 31485, and GB/T 31467.3, covering new energy vehicle batteries, energy storage systems, and consumer electronics batteries.
-
The explosion-proof box is fully customizable. Available volumes include 1m³, 1.5m³, 2m³, 4m³, 6m³, 8m³, and 12m³. Steel plate thickness options are 5mm, 8mm, 10mm, and 12mm, with single or double-layer configurations available to meet different safety and testing requirements.
-
The system supports a maximum short-circuit current range of DC5000A to DC20000A. The specific current rating can be customized according to the application requirements. The contactors are available in two types: a pneumatic vacuum copper short-circuit contactor for resistance less than 5mΩ, and an industrial high current silver surface contactor for 1mΩ to 100mΩ range.