Leave Your Message
High Current Short-circuit Testing Machine from China Suppliers - Reliable Factory for Electrical Safety Testing
Hot Products

High Current Short-circuit Testing Machine from China Suppliers - Reliable Factory for Electrical Safety Testing

Introducing our high-current short-circuit testing machine, a state-of-the-art equipment crafted to replicate sudden short-circuit faults in electrical circuits. This essential device is utilized for conducting comprehensive short-circuit tolerance tests, assessing safety performance and reliability, and performing destructive evaluations on a variety of electrical components, including wiring harnesses, batteries, switches, and connectors. As a leading manufacturer in China, we pride ourselves on providing top-notch testing solutions for electrical safety, product development, and quality certification. Partner with our factory to ensure the highest standards in your electrical products.

    Technical Specifications
    Model TA-DL5000A~20000A (customized)
    Control method Remote computer control + video surveillance
    Max short circuit current DC5000A~DC20000A (customized)
    Contactor 1st type: Resistance < 5mΩ: Pneumatic vacuum copper short-circuit contactor
    2nd type: 1mΩ~100mΩ Industrial high current silver surface contactor
    Arc extinguishing method  
    Contact corresponding time 1st type: ≤20ms
    2nd type: ≤2ms
    Temp range Room temperature / high temperature (customizable)
    Device internal resistance 1st type: resistance < 5mΩ (system short-circuit internal resistance)
    2nd type: Adjustable resistance value of 1mΩ to 100mΩ or higher (optional)
    Insulation resistance DC1500V, 100MΩ Above (between terminal block and side panel)
    Withstand Voltage AC1500V, 1min, leakage current ≤ 5mA
    Resistance material Constantan
    Resistance temperature sensing characteristics ≤50ppm/℃
    Temperature coefficient of resistance α = 5×10⁻⁶ [(0~100℃) 1/℃]
    Resistivity ρ(20℃) = 4.4×10⁻⁷ Ω·m
    Cooling method Forced air cooling of fan
    Explosion proof box (optional) (1) Volume: 1m³ / 1.5m³ / 2m³ / 4m³ / 6m³ / 8m³ / 12m³ customizable
    (2) Steel plate thickness: 5mm / 8mm / 10mm / 12mm; Single or double layered, customizable
    Collection (1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature
    (2) Number of channels; Range; Accuracy; The collection frequency can be customized
    (3) Collection can be built-in or external; External brands are optional
    Test cut-off shutdown conditions The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions
    Curve Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance
    Data Interface Network interface
    Safety device Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc.
    Security protection design Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm
    Power supply AC220V (AC380V) 50HZ 3kW
    Air source The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa
    Multi resistor short-circuit host does not require air source
    Size Air arc extinguishing short circuit host: W700 × D1050 × H1650mm
    Multi resistance high current short-circuit host: W2000 × D1550 × H1750mm (subject to design)
    Weight Vacuum arc extinguishing short-circuit host: 400kg
    Multi resistance high current short-circuit host: 1500kg (subject to design)
    Key Highlights
    • 🛡️ Explosion-Proof Safety DesignEquipped with explosion-proof devices, double-layer explosion-proof steel structure and explosion-proof glass observation windows.
    • 📊 High-Precision Data AcquisitionSupports real-time monitoring of voltage, current, and temperature, as well as curve display.
    • Efficient Arc Extinguishing SystemEffectively suppresses the generation of arcs, prolongs the service life of the contactors.
    • 🔧 Multifunctional Integrated SystemIntegrates a temperature control box, smoke extinguishing system, and video monitoring system into one.
    Compliance & Standards
    UN38.3 IEC 62133 UL 2580 GB 31241 GB/T 31485 GB/T 31467.3
    Safety Systems
    🏗️ Physical Protection Explosion-proof cabinet, pressure relief structure, automatic smoke exhaust.
    🌡️ Environmental Monitoring Intelligent fire extinguishing system.
    🔌 Electrical Protection Emergency stop button, overload protection, short-circuit isolation.
    Application
    • Testing of power batteries for new energy vehicles
    • Performance testing of battery cells and modules for energy storage systems (BESS)
    • Special testing for research institute laboratories
    • Quality inspection of consumer electronic batteries
    Battery Short Circuit Test Equipment Application
    High Current Short Circuit Tester Application
    Battery Safety Testing System
    EV Battery Test Equipment
    Service & Support
    • 📅 Regular CalibrationAssist in the annual calibration of the equipment to ensure test accuracy.
    • 🔩 Installation & CommissioningOffer on-site installation and commissioning services along with professional technical training.
    • 📞 Rapid ResponseProvide 24/7 round-the-clock technical support.
    Workflow
    FAQ
    • This is a common safety hazard existing in the high current test. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured; in case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating.
    • The current during a short circuit changes extremely rapidly (at the millisecond level). Therefore, the equipment adopts a high sampling rate data acquisition module (100kHz and above) combined with high-precision current sensors (such as Rogowski coils, high-frequency shunts, etc.), which can completely capture and record the instantaneous current waveform, ensuring the authenticity and completeness of the test data.
    • Yes. The equipment supports a wide range of voltage levels from DC5V to DC1500V. All you need to do is set the corresponding protection threshold in the software interface, thus truly achieving multi-purpose use with a single machine.
    • The equipment is designed to support testing in compliance with major international and Chinese standards including UN38.3, IEC 62133, UL 2580, GB 31241, GB/T 31485, and GB/T 31467.3, covering new energy vehicle batteries, energy storage systems, and consumer electronics batteries.
    • The explosion-proof box is fully customizable. Available volumes include 1m³, 1.5m³, 2m³, 4m³, 6m³, 8m³, and 12m³. Steel plate thickness options are 5mm, 8mm, 10mm, and 12mm, with single or double-layer configurations available to meet different safety and testing requirements.
    • The system supports a maximum short-circuit current range of DC5000A to DC20000A. The specific current rating can be customized according to the application requirements. The contactors are available in two types: a pneumatic vacuum copper short-circuit contactor for resistance less than 5mΩ, and an industrial high current silver surface contactor for 1mΩ to 100mΩ range.

    Leave Your Message