High Current Short-circuit Testing Machine
Technical Specifications
|
Model |
TA-DL5000A~20000A(customized) |
|
Control method |
Remote computer control+video surveillance |
|
Max short circuit current |
DC5000A~DC20000A......(customized) |
|
Contactor |
1st type: Resistance < 5m Ω: Pneumatic vacuum copper short-circuit contactor 2nd type: 1m Ω~100m Ω Industrial high current silver surface contactor |
|
Arc extinguishing method |
|
|
Contact corresponding time |
1st type:≤20ms 2nd type:≤2ms |
|
Temp range |
Room temperature/high temperature (customizable) |
|
Device internal resistance |
1st type: resistance<5m Ω (system short-circuit internal resistance) 2nd type: Adjustable resistance value of 1m Ω to 100m Ω or higher (optional) |
|
Insulation resistance |
DC1500V,100MΩ Above (between terminal block and side panel) |
|
Withstand Voltage |
AC1500V,1min,leakage current≤5mA |
|
Resistance material |
constantan |
|
Resistance temperature sensing characteristics |
≤50ppm/℃ |
|
Temperature coefficient of resistance |
α= 5x10-6 [(0~100℃)1/℃] |
|
resistivity |
ρ(20℃)=4.4x10-7Ω.m |
|
Cooling method |
Forced air cooling of fan |
|
Explosion proof box (optional) |
(1) Volume: 1m ³/1.5m ³/2m ³/4m ³/6m ³/8m ³/12m ³ customizable (2) Steel plate thickness: 5mm/8mm/10mm/12mm; Single or double layered, customizable |
|
Collection |
(1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature (2) Number of channels; Range; Accuracy; The collection frequency can be customized (3) Collection can be built-in or external; External brands are optional |
|
Test cut-off shutdown conditions |
The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions |
|
Curve |
Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance |
|
Data Interface |
Network interface |
|
Safety device |
Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc |
|
Security protection design |
Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm |
|
Power supply |
AC220V(AC380V) 50HZ 3kW |
|
Air source |
The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa Multi resistor short-circuit host does not require air source |
|
Size |
Air arc extinguishing short circuit host: W700*D1050*H1650mm Multi resistance high current short-circuit host: W2000 * D1550 * H1750mm (subject to design) |
|
Weight |
Vacuum arc extinguishing short-circuit host: 400kg Multi resistance high current short-circuit host: 1500kg (subject to design) |
Key Highlights
Compliance & Standards
Safety Systems
Application
Service & Support
Workflow
FAQ
-
1.What should be done if the contactor gets "stuck" and the current cannot be cut off?
This is a common safety hazard existing in the high current test. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured; in case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating. -
2.How does the equipment capture the instantaneous peak value of short-circuit current?
-
3.Can different voltages be tested?