The high-current short-circuit testing machine is an essential piece of equipment manufactured by leading suppliers in China, designed to accurately simulate sudden short-circuit faults in electrical circuits. This specialized apparatus is crucial for conducting various tests, including short-circuit tolerance, safety performance, reliability, and destructive assessments of electrical components, wiring harnesses, batteries, switches, and connectors. As a vital tool in electrical safety testing, product research and development, and quality certification, this machine plays a significant role in ensuring optimal performance and safety standards in the industry. Discover reliable solutions from our factory, where innovation meets quality for your testing needs.

    Technical Specifications

    Model TA-DL5000A~20000A (customized)
    Control method Remote computer control + video surveillance
    Max short circuit current DC5000A~DC20000A...... (customized)
    Contactor

    1st type: Resistance < 5m Ω: Pneumatic vacuum copper short-circuit contactor

    2nd type: 1m Ω~100m Ω Industrial high current silver surface contactor

    Arc extinguishing method Standard Arc Extinguishing Mechanism
    Contact corresponding time

    1st type: ≤20ms

    2nd type: ≤2ms

    Temp range Room temperature / high temperature (customizable)
    Device internal resistance

    1st type: resistance < 5m Ω (system short-circuit internal resistance)

    2nd type: Adjustable resistance value of 1m Ω to 100m Ω or higher (optional)

    Insulation resistance DC1500V, 100MΩ Above (between terminal block and side panel)
    Withstand Voltage AC1500V, 1min, leakage current ≤5mA
    Resistance material Constantan
    Resistance temperature sensing characteristics ≤50ppm/℃
    Temperature coefficient of resistance α= 5x10-6 [(0~100℃)1/℃]
    Resistivity ρ(20℃)=4.4x10-7Ω.m
    Cooling method Forced air cooling of fan
    Explosion proof box (optional)

    Volume: 1m³ / 1.5m³ / 2m³ / 4m³ / 6m³ / 8m³ / 12m³ customizable

    Steel plate thickness: 5mm / 8mm / 10mm / 12mm; Single or double layered, customizable

    Collection

    (1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature

    (2) Number of channels; Range; Accuracy; The collection frequency can be customized

    (3) Collection can be built-in or external; External brands are optional

    Test cut-off shutdown conditions The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions
    Curve Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance
    Data Interface Network interface
    Safety device Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc
    Security protection design Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm
    Power supply AC220V(AC380V) 50HZ 3kW
    Air source

    The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa

    Multi resistor short-circuit host does not require air source

    Size

    Air arc extinguishing short circuit host: W700*D1050*H1650mm

    Multi resistance high current short-circuit host: W2000 * D1550 * H1750mm (subject to design)

    Weight

    Vacuum arc extinguishing short-circuit host: 400kg

    Multi resistance high current short-circuit host: 1500kg (subject to design)

    Key Highlights

    Explosion-Proof Safety Design

    Equipped with explosion-proof devices, double-layer explosion-proof steel structure and explosion-proof glass observation windows.

    High-Precision Acquisition

    Supports real-time monitoring of voltage, current, and temperature, as well as comprehensive curve display.

    Efficient Arc Extinguishing

    Effectively suppresses the generation of arcs, significantly prolonging the service life of the contactors.

    Multifunctional Integration

    Integrates a temperature control box, smoke extinguishing system, and video monitoring system into one seamless unit.

    Compliance & Standards

    UN38.3 IEC 62133 UL 2580 GB 31241 GB/T 31485 GB/T 31467.3

    Safety Systems

    Physical Protection

    Explosion-proof cabinet, pressure relief structure, and automatic smoke exhaust mechanisms.

    Environmental Monitoring

    Real-time intelligent fire extinguishing and automated thermal monitoring systems.

    Electrical Protection

    Quick-response emergency stop button, comprehensive overload protection, and high-efficiency short-circuit isolation.

    Application

    Testing of power batteries for new energy vehicles
    Performance testing of battery cells and modules for energy storage systems (BESS)
    Special testing for research institute laboratories
    Quality inspection of consumer electronic batteries
    Battery short circuit test application unit
    Battery testing equipment internal chamber
    Short circuit testing machinery setup
    Battery testing lab configuration

    Service & Support

    (1) Regular Calibration

    Assist in the annual calibration of the equipment to ensure test accuracy.

    (2) Installation & Commissioning

    Offer on-site installation and commissioning services along with professional technical training.

    (3) Rapid Response

    Provide 24/7 round-the-clock technical support to guarantee uninterrupted operation.

    Workflow

    Frequently Asked Questions

    1. What should be done if the contactor gets "stuck" and the current cannot be cut off?
    This is a common safety hazard existing in the high current test. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured; in case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating.
    2. How does the equipment capture the instantaneous peak value of short-circuit current?
    The current during a short circuit changes extremely rapidly (at the millisecond level). Therefore, the equipment adopts a high sampling rate data acquisition module (100kHz and above) combined with high-precision current sensors (such as Rogowski coils, high-frequency shunts, etc.), which can completely capture and record the instantaneous current waveform, ensuring the authenticity and completeness of the test data.
    3. Can different voltages be tested?
    OK. Our equipment supports a wide range of voltage levels. All you need to do is set the corresponding protection threshold in the software interface, thus truly achieving multi-purpose use with a single machine.
    4. What are the cut-off shutdown conditions for the short-circuit test?
    The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions, providing flexible and automated protection during multi-channel testing.
    5. Is the explosion-proof chamber customizable for different battery sizes?
    Yes. The explosion-proof box can be customized in volumes ranging from 1m³ up to 12m³, with steel plate thickness options from 5mm to 12mm in single or double-layered configurations according to laboratory requirements.
    6. What international standards does this short-circuit test system comply with?
    The equipment fully complies with mainstream international and national test regulations including UN38.3, IEC 62133, UL 2580, GB 31241, GB/T 31485, and GB/T 31467.3.