0102030405
High Current Short-Circuit Testing Machine - Reliable China Suppliers & Factory for Electrical Safety Testing
Technical Specifications
| Model | TA-DL5000A~20000A (customized) |
| Control method | Remote computer control + video surveillance |
| Max short circuit current | DC5000A~DC20000A (customized) |
| Contactor |
1st type: Resistance < 5mΩ: Pneumatic vacuum copper short-circuit contactor 2nd type: 1mΩ~100mΩ Industrial high current silver surface contactor |
| Arc extinguishing method | Vacuum / Air Arc Extinguishing |
| Contact corresponding time |
1st type: ≤20ms 2nd type: ≤2ms |
| Temp range | Room temperature / high temperature (customizable) |
| Device internal resistance |
1st type: resistance < 5mΩ (system short-circuit internal resistance) 2nd type: Adjustable resistance value of 1mΩ to 100mΩ or higher (optional) |
| Insulation resistance | DC1500V, 100MΩ Above (between terminal block and side panel) |
| Withstand Voltage | AC1500V, 1min, leakage current ≤ 5mA |
| Resistance material | constantan |
| Resistance temperature sensing characteristics | ≤50ppm/℃ |
| Temperature coefficient of resistance | α = 5x10-6 [(0~100℃) 1/℃] |
| resistivity | ρ(20℃) = 4.4x10-7Ω.m |
| Cooling method | Forced air cooling of fan |
| Explosion proof box (optional) |
(1) Volume: 1m³ / 1.5m³ / 2m³ / 4m³ / 6m³ / 8m³ / 12m³ customizable (2) Steel plate thickness: 5mm / 8mm / 10mm / 12mm; Single or double layered, customizable |
| Collection |
(1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature (2) Number of channels; Range; Accuracy; The collection frequency can be customized (3) Collection can be built-in or external; External brands are optional |
| Test cut-off shutdown conditions | The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions |
| Curve | Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance |
| Data Interface | Network interface |
| Safety device | Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc |
| Security protection design | Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm |
| Power supply | AC220V (AC380V) 50HZ 3kW |
| Air source |
The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa Multi resistor short-circuit host does not require air source |
| Size |
Air arc extinguishing short circuit host: W700*D1050*H1650mm Multi resistance high current short-circuit host: W2000 * D1550 * H1750mm (subject to design) |
| Weight |
Vacuum arc extinguishing short-circuit host: 400kg Multi resistance high current short-circuit host: 1500kg (subject to design) |
Key Highlights
Explosion-proof safety design
Equipped with explosion-proof devices, double-layer explosion-proof steel structure and explosion-proof glass observation windows.
High-precision data acquisition
Supports real-time monitoring of voltage, current, and temperature, as well as curve display.
Efficient arc extinguishing system
Effectively suppresses the generation of arcs, prolonging the service life of the contactors.
Multifunctional integrated system
Integrates a temperature control box, smoke extinguishing system, and video monitoring system into one.
Compliance & Standards
UN38.3
IEC 62133
UL 2580
GB 31241
GB/T 31485
GB/T 31467.3
Safety Systems
Physical Protection
Explosion-proof cabinet, pressure relief structure, automatic smoke exhaust.
Environmental Monitoring
Intelligent fire extinguishing system.
Electrical Protection
Emergency stop button, overload protection, short-circuit isolation.
Application
- Testing of power batteries for new energy vehicles
- Performance testing of battery cells and modules for energy storage systems (BESS)
- Special testing for research institute laboratories
- Quality inspection of consumer electronic batteries
Service & Support
(1) Regular calibration
Assist in the annual calibration of the equipment to ensure test accuracy.
(2) Installation and commissioning
Offer on-site installation and commissioning services along with professional technical training.
(3) Rapid response
Provide 24/7 round-the-clock technical support.
Workflow
Frequently Asked Questions
1. What should be done if the contactor gets "stuck" and the current cannot be cut off?
This is a common safety hazard existing in high current tests. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured. In case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating.
2. How does the equipment capture the instantaneous peak value of short-circuit current?
The current during a short circuit changes extremely rapidly (at the millisecond level). Therefore, the equipment adopts a high sampling rate data acquisition module (100kHz and above) combined with high-precision current sensors (such as Rogowski coils, high-frequency shunts, etc.), which can completely capture and record the instantaneous current waveform, ensuring the authenticity and completeness of the test data.
3. Can different voltages be tested?
Yes. Our equipment supports a wide range of voltage levels. All you need to do is set the corresponding protection threshold in the software interface, thus truly achieving multi-purpose use with a single machine.
4. What cooling method is used, and does the system require an external air source?
The system utilizes forced air cooling via internal fans. Regarding the air source: the vacuum arc extinguishing short-circuit host requires a compressed external air source of ≥ 0.6MPa to operate its pneumatic components, whereas the multi-resistor short-circuit host does not require any external air source.
5. What safety protection features are designed into the testing system?
The system features multi-layered security protection design, including overtemperature protection, overload protection, access control safety links, a physical emergency stop switch, and a three-color light status alarm. Additionally, it can be paired with an optional explosion-proof box made of 5mm to 12mm thick steel plates featuring smoke exhaust and fire extinguishing systems.
6. How are test cut-off conditions managed during battery short-circuit tests?
The software allows users to configure specific cut-off conditions. The battery's temperature, voltage levels, and total short-circuit duration can be set individually or combined as conditional logic parameters to automatically trigger a safe shutdown and isolate the system during test cycles.

Home