Leave Your Message
High Current Short-Circuit Testing Machine - Reliable China Suppliers & Factory for Electrical Safety Testing
Hot Products

High Current Short-Circuit Testing Machine - Reliable China Suppliers & Factory for Electrical Safety Testing

,

Introducing our high-current short-circuit testing machine, a top-tier testing solution crafted in China. This specialized equipment is engineered to replicate sudden short-circuit faults in electrical circuits. It is ideal for evaluating the short-circuit tolerance, safety performance, reliability, and durability of various electrical components, including wiring harnesses, batteries, switches, and connectors. As one of the leading suppliers in the industry, our factory ensures that this indispensable equipment meets the rigorous standards required for electrical safety testing, product development, and quality certification. Trust our advanced technology to enhance your product testing capabilities.

,

    Technical Specifications

    Model TA-DL5000A~20000A (customized)
    Control method Remote computer control + video surveillance
    Max short circuit current DC5000A~DC20000A (customized)
    Contactor 1st type: Resistance < 5mΩ: Pneumatic vacuum copper short-circuit contactor
    2nd type: 1mΩ~100mΩ Industrial high current silver surface contactor
    Arc extinguishing method Vacuum / Air Arc Extinguishing
    Contact corresponding time 1st type: ≤20ms
    2nd type: ≤2ms
    Temp range Room temperature / high temperature (customizable)
    Device internal resistance 1st type: resistance < 5mΩ (system short-circuit internal resistance)
    2nd type: Adjustable resistance value of 1mΩ to 100mΩ or higher (optional)
    Insulation resistance DC1500V, 100MΩ Above (between terminal block and side panel)
    Withstand Voltage AC1500V, 1min, leakage current ≤ 5mA
    Resistance material constantan
    Resistance temperature sensing characteristics ≤50ppm/℃
    Temperature coefficient of resistance α = 5x10-6 [(0~100℃) 1/℃]
    resistivity ρ(20℃) = 4.4x10-7Ω.m
    Cooling method Forced air cooling of fan
    Explosion proof box (optional) (1) Volume: 1m³ / 1.5m³ / 2m³ / 4m³ / 6m³ / 8m³ / 12m³ customizable
    (2) Steel plate thickness: 5mm / 8mm / 10mm / 12mm; Single or double layered, customizable
    Collection (1) Current DC5000A~DC20000A; Voltage range from DC5V to DC1500V; temperature
    (2) Number of channels; Range; Accuracy; The collection frequency can be customized
    (3) Collection can be built-in or external; External brands are optional
    Test cut-off shutdown conditions The temperature, voltage, and short-circuit time of the battery are used individually or in combination as test cut-off shutdown conditions
    Curve Real time monitoring and synchronous display of temperature, voltage, short-circuit current, and short-circuit time of multi-channel batteries, facilitating analysis of battery safety performance
    Data Interface Network interface
    Safety device Video surveillance system, safety and explosion-proof system, smoke emission system, smoke alarm device, explosion-proof lighting device, etc
    Security protection design Overtemperature protection; Overload protection; Equipped with leakage protection device, access control, safety emergency stop switch, and three color light alarm
    Power supply AC220V (AC380V) 50HZ 3kW
    Air source The vacuum arc extinguishing short circuit device requires a compressed air source of ≥ 0.6MPa
    Multi resistor short-circuit host does not require air source
    Size Air arc extinguishing short circuit host: W700*D1050*H1650mm
    Multi resistance high current short-circuit host: W2000 * D1550 * H1750mm (subject to design)
    Weight Vacuum arc extinguishing short-circuit host: 400kg
    Multi resistance high current short-circuit host: 1500kg (subject to design)

    Key Highlights

    Explosion-proof safety design
    Equipped with explosion-proof devices, double-layer explosion-proof steel structure and explosion-proof glass observation windows.
    High-precision data acquisition
    Supports real-time monitoring of voltage, current, and temperature, as well as curve display.
    Efficient arc extinguishing system
    Effectively suppresses the generation of arcs, prolonging the service life of the contactors.
    Multifunctional integrated system
    Integrates a temperature control box, smoke extinguishing system, and video monitoring system into one.

    Compliance & Standards

    UN38.3 IEC 62133 UL 2580 GB 31241 GB/T 31485 GB/T 31467.3

    Safety Systems

    Physical Protection
    Explosion-proof cabinet, pressure relief structure, automatic smoke exhaust.
    Environmental Monitoring
    Intelligent fire extinguishing system.
    Electrical Protection
    Emergency stop button, overload protection, short-circuit isolation.

    Application

    • Testing of power batteries for new energy vehicles
    • Performance testing of battery cells and modules for energy storage systems (BESS)
    • Special testing for research institute laboratories
    • Quality inspection of consumer electronic batteries

    Service & Support

    (1) Regular calibration
    Assist in the annual calibration of the equipment to ensure test accuracy.
    (2) Installation and commissioning
    Offer on-site installation and commissioning services along with professional technical training.
    (3) Rapid response
    Provide 24/7 round-the-clock technical support.

    Workflow

    Frequently Asked Questions

    1. What should be done if the contactor gets "stuck" and the current cannot be cut off?
    This is a common safety hazard existing in high current tests. To address this, the equipment adopts a dual physical disconnection protection mechanism: in addition to the main contactor, an emergency safety air switch or physical fuse device is also configured. In case of abnormal conditions, forced power-off can be achieved through the secondary circuit, effectively avoiding the risk of fire caused by continuous overheating.
    2. How does the equipment capture the instantaneous peak value of short-circuit current?
    The current during a short circuit changes extremely rapidly (at the millisecond level). Therefore, the equipment adopts a high sampling rate data acquisition module (100kHz and above) combined with high-precision current sensors (such as Rogowski coils, high-frequency shunts, etc.), which can completely capture and record the instantaneous current waveform, ensuring the authenticity and completeness of the test data.
    3. Can different voltages be tested?
    Yes. Our equipment supports a wide range of voltage levels. All you need to do is set the corresponding protection threshold in the software interface, thus truly achieving multi-purpose use with a single machine.
    4. What cooling method is used, and does the system require an external air source?
    The system utilizes forced air cooling via internal fans. Regarding the air source: the vacuum arc extinguishing short-circuit host requires a compressed external air source of ≥ 0.6MPa to operate its pneumatic components, whereas the multi-resistor short-circuit host does not require any external air source.
    5. What safety protection features are designed into the testing system?
    The system features multi-layered security protection design, including overtemperature protection, overload protection, access control safety links, a physical emergency stop switch, and a three-color light status alarm. Additionally, it can be paired with an optional explosion-proof box made of 5mm to 12mm thick steel plates featuring smoke exhaust and fire extinguishing systems.
    6. How are test cut-off conditions managed during battery short-circuit tests?
    The software allows users to configure specific cut-off conditions. The battery's temperature, voltage levels, and total short-circuit duration can be set individually or combined as conditional logic parameters to automatically trigger a safe shutdown and isolate the system during test cycles.

    Leave Your Message