Leave Your Message
High-Low Temperature and Humidity Test Chamber - Reliable Testing Equipment from China Suppliers & Factory
Hot Products

High-Low Temperature and Humidity Test Chamber - Reliable Testing Equipment from China Suppliers & Factory

Introducing our cutting-edge high and low temperature and humidity test chamber, designed as a reliable testing equipment to simulate the combined environmental conditions of temperature and humidity. Manufactured in China, this advanced chamber allows suppliers to simultaneously control low temperatures, high temperatures, constant humid heat, and alternating humid heat. It is essential for testing the moisture-proof capabilities, insulation, mold prevention, and structural stability of products in both humid and fluctuating hot and cold environments. Trust our factory for high-quality and efficient testing solutions tailored for your needs.

    Technical Specifications

    Model TAH-23L TAH-64L TAH-80L TAH-100L TAH-120L TAH-150L TAH-225L TAH-408L TAH-800L TAH-1000L
    Control System Balance temperature and humidity control system
    Temperature range -20℃~150℃;-40℃~150℃;-70℃~150℃
    (Rapid temperature change, linear throughout the entire process, non-linear selectable)
    Humidity range 20℃~98%R.H
    Temperature fluctuation ±0.5℃
    Humidity fluctuation ±2.5%R.H
    Temperature deviation ±2.0℃
    Humidity deviation ±3%R.H(≥75%R.H) / ±5%R.H(<75%R.H)
    Heating up time -20℃~150℃ around 45 minutes;-40℃~150℃ around 60 minutes;-70℃~150℃ around 75 minutes
    Cooling time 20℃~-20℃ around 40 minutes;20℃~-40℃ around 60 minutes;20℃~-70℃ around 85 minutes
    Inner size (cm) W 30 40 40 50 50 50 60 68 100 100
    H 30 40 50 50 50 60 75 80 100 100
    D 25 40 40 40 48 50 50 75 80 100
    Outer size (cm) W 50 60 60 70 70 70 80 88 120 120
    H 125 140 155 155 155 161 171 176 195 195
    D 90 110 110 115 123 125 125 150 155 175
    Inner material SUS304 Advanced stainless steel
    Outer material Cold rolled steel plate surface treatment by electrostatic spraying or SUS304 high-grade stainless steel
    Insulation material High density polyurethane foam and glass fiber
    Freezing system Air cooled (optional water-cooled)
    Controller LCD color touch screen, Chinese/English display, program, communication function
    Protector Non fuse switch, compressor overpressure, overheating, overcurrent protection, overtemperature protection, fan overload protection, fuse, dry burning machine protector, water shortage protection switch, fault warning system, alarm
    Standard accessories One observation window for the three-layer vacuum layer, one Ø 5cm test hole, two sets of experimental racks, one illumination board inside the box, four indicator lights, four mobile work wheels, one humidification water tank, a 2-meter power cord, and a communication interface (customizable according to requirements)
    Environmental temperature for use 5℃~35℃
    Supply power AC380±10% 50HZ Three-phase four wire + PE

    Key Highlights

    (1) External Humidifier

    Easy to clean, less prone to scaling.

    (2) Water System

    Supports automatic water replenishment, highly water-saving.

    (3) Water Quality Filtration

    Built-in ion exchange resin filtration, which can effectively prevent the humidifier from getting clogged.

    (4) Observation Window

    Made of multi-layer vacuum heated tempered glass, ensuring no frosting or condensation even in low-temperature and high-humidity environments, keeping the view completely clear.

    How to Choose a Sensor?

    Dry-Wet Bulb Method
    Easy to maintain, resistant to high temperature and humidity, suitable for most industrial testing scenarios.
    Capacitive Sensor
    Quick response, no need to replace the gauze, suitable for low humidity environments and high-precision scientific research testing.

    Application

    Food shelf life testing Pharmaceutical stability test Paint coating Plastic rubber

    Compliance & Standards

    GB/T 2423.1/2/3/4
    MIL-STD-202G
    IEC 60068-2-78

    Frequently Asked Questions (FAQ)

    1. Why use pure water or distilled water?
    The impurities present in tap water can easily form scale, causing blockages in the humidification pipeline and reducing the accuracy of the humidity sensor's detection.
    2. How often should the humidity sensor wick be replaced?
    Based on the water quality and usage frequency, it is recommended to replace it every 3 months. This device comes with a box of replacement parts as a standard.
    3. Can the equipment undergo a stability test lasting for 30 days or even longer?
    Yes. The equipment is equipped with an automatic water replenishment function in case of water shortage and multiple protection functions against overheating. It fully supports long-term continuous operation without human intervention.
    4. What cooling options are available for the freezing system?
    The system comes standard with an air-cooled refrigeration setup, and water-cooled systems are optionally selectable depending on facility conditions.
    5. What type of power supply is required to operate this chamber?
    The required electrical supply is AC380V ±10% 50Hz, three-phase four-wire + protective earth (PE).
    6. How does the observation window prevent condensation during low-temperature cycles?
    The observation window features multi-layer vacuum heated tempered glass that prevents frost and condensation from forming, ensuring a clear visual path throughout all test phases.

    Leave Your Message