0102030405
Thermal Runaway Testing Machine from China Suppliers and Factory for Lithium Battery Safety Assessment
Technical Specifications
| Name | Thermal Runaway Testing Machine | |
| Model | TA-RSK-PC | |
| Control Method | Remote computer control + video surveillance | |
| Trigger Mode | Overcharge and heating modes (standard) | |
| DC Overcharge Trigger Control Parameters | Control Object | Overcharge control of individual battery cells |
| Control Method | Computer programming control; Controllable overcharge current and voltage | |
| Controller | Programmable intelligent DC power supply | |
| Number of Channels | 1 channel | |
| Overcharge Voltage Range | 0~10V adjustable (customized) | |
| Overcharge Voltage Accuracy | ≤0.3% + 2LSB | |
| Overcharge Voltage Resolution | 0.001V | |
| Overcharge Current Range | 0~300A adjustable (customized) | |
| Overcharge Current Accuracy | ≤0.3% + 2LSB | |
| Overcharge Current Resolution | 0.1A | |
| Exchange Heating Trigger Control Parameters | Control Object | Heating element: Heating plate (maximum power 3kw); Customizable size and power according to requirements |
| Control Mode | Computer programming control 1: Controllable rate control: 4-7 ℃/min; Adjustable temperature rise rate 2: Multi-step or power progressive control can be performed on each heating plate (e.g., 50W/min to 500W/min; Power can be set arbitrarily) 3. Synchronized generation of curves to reflect testing status realistically and intuitively |
|
| Controller | Programmable intelligent AC variable frequency power supply | |
| Channels | 1 channel AC220V-3kW | |
| Output | Phase: 1Ø 2W; Phase voltage: Low 0-150VAC / High 0-300VAC; Frequency: 45-200Hz, 0.1 Step; Max current: L=200V-25A / H=400V-12.5A | |
| LED Display | Voltage Vrms, Current Arms, Frequency Fre, Power Wattage, Power Factor PF | |
| Power Supply Stabilization Rate | 0.1% | |
| Load Regulation | 1% | |
| Measurement Accuracy | Voltage: 0.5%FS+5dgt | Current: 0.5%FS+5dgt | Power: 0.5%FS+5dgt | Frequency: 0.01%FS+5dgt | |
| Setting Accuracy | Voltage: 1%FS | Frequency: 0.1%FS | |
| Current Limiting Setting | 0-Max Current (Power protection for exceeding setting value, stop output) | |
| Protection | Over Current, Over Temp, Short Circuit, Over Load | |
| Communication Interface | RS232C | |
| Data Acquisition System | Voltage Acquisition Channel | 2 channels |
| Voltage Collection Range | 0-10V | |
| Voltage Acquisition Accuracy | ≤0.2% FSR | |
| Voltage Acquisition Frequency | 50Hz | |
| Temperature Acquisition Channel | 4 channels | |
| Temp Collection Range | 0~800℃ | |
| Temp Acquisition Accuracy | ±1℃ | |
| Temp Acquisition Frequency | 50Hz | |
| Monitor System | Camera resolution: 1080P, 5 million pixels | |
| Explosion Proof Box (Optional) | (1) Volume: 1m³ / 1.5m³ / 2m³ customizable (2) Steel plate thickness: 5mm / 8mm / 10mm; Single or double layered, customizable |
|
| Equipment Size | Power control host: W750 * D750 * H1200 mm; Customized explosion-proof box size | |
| Equipment Weight | Power control host: 50kg; Explosion proof box: 0.5t~2t (optional) | |
| Equipment Power Supply | AC220V / AC380V | |
| Total Power | 4KW | |
Triggering Capabilities
(1) Needle Penetration Trigger
Equipped with various diameters ranging from 3mm to 8mm steel needles, it supports high-precision displacement control and adjustable puncture speed, precisely simulating the internal short circuit caused by foreign object puncture.
(2) High-temperature Heating
Using ceramic heating, flexible heating sheets or induction heating methods, it can rapidly increase the temperature from room temperature to the heat runaway trigger point, with precise and stable temperature control.
(3) Overcharge Trigger
The built-in high current and high voltage charging and discharging interface enables direct triggering of overcharge and overdischarge and other types of electrical abuse.
(4) Laser Triggering
By leveraging the high energy density characteristic of lasers, we can achieve localized, non-contact, and precise thermal triggering.
Safety Features
(1) Explosion-proof Structural Design
Utilizing a high-strength stainless steel inner tank combined with a reinforced frame structure, it can withstand the instantaneous shock pressure generated by battery thermal runaway.
(2) Pressure Relief Window / Explosion-proof Door
Equipped with a mechanical automatic pressure relief device, which opens quickly to release pressure in case of overpressure.
(3) Exhaust Gas Treatment System
Supports built-in or external smoke gas purification units, which can effectively filter out toxic and corrosive gases such as HF and CO.
(4) Fire Extinguishing and Cooling System
Equipped with automatic fire suppression spraying and emergency nitrogen blowing functions, which can quickly suppress the fire.
Standards Compliance
GB 38031-2020
UL 2580
IEC 62133 / IEC 62619
UN 38.3
Data Acquisition & Analysis
(1) Multi-channel Temperature Monitoring
Supports 16/32 channels of K/T type thermocouples, for real-time collection of battery multi-point temperatures.
(2) Voltage and Pressure Monitoring
Synchronously records voltage drops and changes in cabin pressure.
(3) Gas Composition Analysis
Optional gas analyzer can be equipped to monitor concentrations of H₂, O₂, CO, etc.
(4) Synchronized Curve Display
Video and temperature, pressure, and electrical signals are displayed simultaneously in real time.
Frequently Asked Questions (FAQ)
1. After a fire or explosion test, will the test cabin be able to be reused?
The equipment is specifically designed for battery destructive testing:
• Corrosion Resistance: The inner liner is made of 304/316 corrosion-resistant stainless steel, which can be directly cleaned with a high-pressure water gun, making maintenance very convenient.
• Modular Design for Wearable Parts: The needle assembly and heating plate are both built with a quick-change structure, making replacement easy.
• High Reusability: Simply clean up combustion residues promptly and check the sensor lines; the chamber is then ready for repeated testing without frequent factory overhauls.
• Corrosion Resistance: The inner liner is made of 304/316 corrosion-resistant stainless steel, which can be directly cleaned with a high-pressure water gun, making maintenance very convenient.
• Modular Design for Wearable Parts: The needle assembly and heating plate are both built with a quick-change structure, making replacement easy.
• High Reusability: Simply clean up combustion residues promptly and check the sensor lines; the chamber is then ready for repeated testing without frequent factory overhauls.
2. How can we ensure the consistency of ignition temperature control and avoid fluctuations in experimental data?
The equipment adopts precision closed-loop control to guarantee reproducibility:
1. Displacement Control: A precision servo motor drives the needle with a positioning accuracy of ±0.1mm.
2. Temperature Control Compensation: Uses PID constant temperature regulation to eliminate ambient temperature shifts and power supply fluctuations.
1. Displacement Control: A precision servo motor drives the needle with a positioning accuracy of ±0.1mm.
2. Temperature Control Compensation: Uses PID constant temperature regulation to eliminate ambient temperature shifts and power supply fluctuations.
3. After thermal runaway occurs, how should the toxic and harmful smoke generated be dealt with?
Thermal runaway produces corrosive and toxic by-products such as HF, CO, and volatile hydrocarbons.
The system comes equipped with a dedicated exhaust duct interface designed to link directly with laboratory scrubbers or emission purification systems. After testing, it automatically initiates forced ventilation, routing exhaust gas through multi-stage filtration (including activated carbon and alkaline scrubbing) to comply with environmental and occupational safety regulations.
The system comes equipped with a dedicated exhaust duct interface designed to link directly with laboratory scrubbers or emission purification systems. After testing, it automatically initiates forced ventilation, routing exhaust gas through multi-stage filtration (including activated carbon and alkaline scrubbing) to comply with environmental and occupational safety regulations.
4. Which international battery safety testing standards does this equipment support?
The TA-RSK-PC fully complies with major international electric vehicle and energy storage battery safety standards, including GB 38031-2020, UL 2580, IEC 62133, IEC 62619, and UN 38.3 thermal propagation test mandates.
5. What channels and data acquisition rates are provided for synchronized analysis?
The machine includes 2 voltage measurement channels (0-10V, 50Hz, accuracy ≤0.2% FSR) and 4 high-temperature thermocouple channels (0-800℃, 50Hz, accuracy ±1℃). It can expand to 16/32 channels and synchronizes these electrical and thermal curves with 1080P high-definition video feeds.
6. Can the explosion-proof chamber volume and steel thickness be customized?
Yes. The optional explosion-proof chamber is customizable to standard capacities of 1m³, 1.5m³, or 2m³, with wall plate thicknesses of 5mm, 8mm, or 10mm in single- or double-layered configurations, engineered to specific battery cell capacities and explosive force requirements.

Home