Thermal Runaway Testing Machine
Technical Specifications
|
Name |
Thermal Runaway Testing Machine |
|
|
Model |
TA-RSK-PC |
|
|
Control Method |
Remote computer control + video surveillance |
|
|
Trigger Mode |
Overcharge and heating modes (standard) |
|
|
DC overcharge trigger control parameters |
Control Object |
Overcharge control of individual battery cells |
|
Control Method |
Computer programming control Controllable overcharge current and voltage |
|
|
Controller |
Programmable intelligent DC power supply |
|
|
Number of overcharge mode channels |
1channel |
|
|
Overcharge voltage range |
0~10V adjustable(customized) |
|
|
Overcharge voltage accuracy |
≤0.3%+2LSB |
|
|
Overcharge voltage resolution |
0.001V |
|
|
Overcharge current range |
0~300A adjustable(customized) |
|
|
Overcharge current accuracy |
≤0.3%+2LSB |
|
|
Overcharge current resolution |
0.1A |
|
|
Exchange heating trigger control parameters
|
Control Object |
Heating element: Heating plate (maximum power 3kw) Customizable size and power according to requirements |
|
control mode |
Computer programming control 1: Controllable rate control: 4-7 ℃/min; Adjustable temperature rise rate 2: Multi step or power progressive control can be performed on the power of each heating plate, such as power progressive control from 50W/min to 500W/min; Power can be set arbitrarily 3. Synchronize the generation of curves to reflect the testing status more realistically and intuitively |
|
|
Controller |
Programmable intelligent AC variable frequency power supply |
|
|
Channles |
1channel AC220V-3kW |
|
|
Output
|
Phase:1¢2w ; Phase voltage: Low 0-150VAC/high 0-300VAC; Frequency: 45- 200Hz,0.1Step ; Max current:L=200V-25A / H=400V-12.5A |
|
|
LED display
|
Voltage Vrms、 Current Arms、 Frequency Fre、 Power Wattage、 Power Factor PF |
|
|
Power supply stabilization rate |
0.1% |
|
|
load regulation |
1% |
|
|
Measurement accuracy |
Voltage:0.5%FS+5dgt Current:0.5%FS+5dgt Power:0.5%FS+5dgt Frequency:0.01%FS+5dgt |
|
|
Set accuracy |
Voltage:1%FS Frequency:0.1%FS |
|
|
Current limiting setting |
O-Max Current(Power protection for exceeding current setting value, stop output) |
|
|
Proetction |
Over Current, Over Temp Short Circuit,Over Load |
|
|
Communication interface |
RS232C |
|
|
Data Acquisition System |
Voltage acquisition channel: 2 channels |
|
|
Voltage collection range:0-10v |
||
|
Voltage acquisition accuracy:≤0.2%FSR |
||
|
Voltage acquisition frequency:50HZ |
||
|
Temperature acquisition channel: 4 channels |
||
|
Temp collection range:0~800℃ |
||
|
Temp acquisition accuracy:±1℃ |
||
|
Temp acquisition frequency:50HZ |
||
|
Monitor system |
Camera resolution:1080P, 5 million pixels; |
|
|
Explosion proof box (optional) |
(1) Volume: 1m ³/1.5m ³/2m ³ customizable (2) Steel plate thickness: 5mm/8mm/10mm; Single or double layered, customizable |
|
|
Equipment size |
Power control host: W750 * D750* H1200 mm; Customized explosion-proof box size |
|
|
Equipment weight |
Power control host: 50kg Explosion proof box: 0.5t~2t (optional) |
|
|
Equipment power suuply |
AC220V /AC380V |
|
|
Total power |
4KW |
|
Triggering Capabilities
Safety Features
Standards Compliance
Data Acquisition & Analysis
FAQ
-
1.After a fire or explosion test, will the test cabin be able to be reused?
-
2.How can we ensure the consistency of the ignition temperature control and avoid fluctuations in experimental data?
The equipment adopts closed-loop control:
1. Displacement control: Servo motor drives the needle, with an accuracy of ±0.1mm
2. Temperature control compensation: PID constant temperature regulation, eliminating environmental errors -
3.After a thermal runaway occurs, how should the toxic and harmful smoke generated be dealt with?
The thermal runaway of the battery will produce toxic and corrosive smoke such as HF, CO, and hydrocarbons.
The equipment is equipped with a dedicated smoke treatment interface, which can be linked to the laboratory scrubber or purification system. After the test, it will automatically expel the air forcefully, and the exhaust gas will be filtered through multiple stages including activated carbon and alkaline washing, achieving compliance with emission standards and protecting the laboratory environment and personnel safety.

Home